Visatron VN2020 Oil Mist Detector
The Visatron VN2020 Oil Mist Detector is the successor to the Visatron VN87Plus.
The Visatron VN2020 Oil Mist Detector is the successor to the Visatron VN87Plus. The VN2020 is designed for diesel, gas and dual-fuel engines and can check up multiple measuring points simultaneously via an engine-specific mounting kit for complete monitoring of the crankcase. When the oil mist concentration increases at one of the measuring points, an alarm is triggered. The Visatron VN2020 protects the engine preventively, permanently and reliably, contributing to the safety of operator and machine.
The VN2020 is designed for easy retrofitting of the older Visatron VN87, VN87Plus and VN93 Oil Mist Detectors.
The new, environmentally friendly fuels pose new challenges when it comes to engines and their components. The new Visatron VN2020 is the worlds first explosion-protected oil mist detector that complies with both
Features
ATEX and IECEx guidelines.
ATEX and IECEx certifications
Low costs
New pressure regulator unit
User-friendly, easy-to-read LED display
CANopen and Modbus RTU connectivity
Reset button at central point on the measuring unit
The system is designed to correspond to the lifespan of the engine and entails only minimal maintenance costs.
Minimized total cost of ownership (TCO).
Certified by all classification societies.
| Dimensions |
623 x 298 x 171 mm |
|---|---|
| Weight |
12.5 kg |
| Installation |
4 x M8 |
| Housing |
Aluminium |
| Operating temperature |
5°C – 70°C |
| Storage temperature |
-25°C – 80°C |
| Humidity |
Max. 95% |
| IP Rating |
IP 54 |
| Power supply |
18-31,2 V DC |
| Nominal voltage |
24 V DC |
| Current consumption |
Max. 2A |
| Display parameters |
Error indicator ,Oil mist concentration ,Reset button ,System status |
| Relay outputs |
1 – Oil Mist Pre-Alarm (max. 60 Volt AC / DC, 1A) ,1 – Ready (ready for operation) ,2 – High Oil Mist Alarm |
| Communication interface with monitoring device |
3-wire RS485, electrically isolated/CANopen, electrically isolated |
| Memory |
Events: 8000 |
| Compressed air supply |
Min. 2 bar – Max. 12 bar |
| Compressed air consumption |
1,2 Nm3/h |
| Compressed air connection, pressure regulator |
M16 x 1,5 |
| Air quality |
ISO 8573-1:2010 (6-4-4) |