Haes Esento Marine 2 Zone Conventional Fire Alarm Control Panel
The Haes Esento Marine 2 Zone is a conventional marine approved fire alarm control panel.
Haes Esento Marine 2 Zone Fire Alarm Control Panel
The Haes Esento Marine 2 Zone is a marine-approved conventional fire alarm control panel designed to provide reliable fire detection and alarm management on vessels. Approved by MED, Lloyd’s Register, and ABS, the panel meets marine industry requirements and is fitting for installation across a wide range of commercial and offshore vessels.
Supporting 2 conventional detection zones, the Esento Marine 2 Zone combines direct operation with practical fire alarm management features, including muster alarm functionality, false alarm management, and non-latching zone configuration. Operators can access panel controls via a key switch or code entry, helping prevent unauthorized operation.
The panel is fully compatible with Apollo Orbis Marine detectors and incorporates detector removal monitoring, earth fault monitoring, and monitored sounder circuits to ensure reliable system supervision. Unlike larger Esento Marine panels, the 2-zone version does not support networking or repeater panel functionality.
Key Features
- 2 conventional fire detection zones
- Marine approved (MED, Lloyd’s Register, ABS)
- Key switch or code entry controlled operation
- Compatible with Apollo Orbis Marine detectors
- Integral detector removal monitoring
- Earth fault monitoring
- Muster alarm functionality
- False alarm management mode
- Non-latching zone support
- Test mode with or without sounders
- Zone, sounder and auxiliary output disable functions
- Fire and fault switched negative outputs
- Class change input
- Alert input
- Easy installation and operation
Typical Applications
The Esento Marine 2 Zone provides reliable fire detection and alarm management for smaller marine installations.
Common applications include:
- Small commercial vessels
- Workboats
- Fishing vessels
- Offshore support craft
- Accommodation areas
- Machinery spaces
- Utility rooms
- Marine service vessels
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Name | Haes Esento Marine 2 Zone |
| System Type | Conventional Marine Fire Alarm Control Panel |
| Number of Zones | 2 |
| Marine Approvals | MED, Lloyd’s Register, ABS |
| Detector Compatibility | Apollo Orbis Marine Detectors |
| Power Supply | 1.25 Amp Switch Mode PSU |
| Nominal Output Voltage | 27 VDC |
| Sounder Outputs | 2 Monitored Outputs |
| Auxiliary Relays | 2 Voltage-Free Change-Over Relays |
| Fire Relay | 1 |
| Fault Relay | 1 |
| Auxiliary Inputs | Class Change Input, Alert Input |
| Fault Monitoring | Earth Fault Monitoring |
| Detector Monitoring | Detector Removal Monitoring |
| False Alarm Management | Yes |
| Muster Alarm | Yes |
| Test Function | With or Without Sounders |
| Disable Functions | Zones, Sounders and Auxiliary Outputs |
| Alarm Load Capacity | 800 mA Shared Across Sounder Outputs |
| Sounder Circuit Protection | Resettable Fuses, 500 mA per Circuit |
| Networking | Not Supported |
| Repeater Panels | Not Supported |
Installation Characteristics
| Parameter | Description |
|---|---|
| Control Panel Type | Conventional Marine Fire Alarm Panel |
| Installation Environment | Marine and Offshore Applications |
| User Access | Key Switch or PIN Code |
| Detector Support | Apollo Orbis Marine Range |
| Monitoring Functions | Earth Fault and Detector Removal Monitoring |
| Alarm Management | False Alarm Mode and Muster Alarm |
| Typical Service | Fire Detection and Alarm Control |
Related products
Need some help with your project?
Send an enquiry or contact us directly and we will try our best to help you.