Kidde Graviner MK5 Oil Mist Detector System

The Kidde Graviner MK5 Oil Mist Detector System is a crankcase protection system designed to continuously monitor oil mist concentrations within diesel engine crankcases.

Kidde Graviner MK5 Oil Mist Detector System

The Kidde Graviner MK5 Oil Mist Detector System continuously monitors oil mist concentrations within diesel engine crankcases, providing early warning of overheating bearings, lubrication failures, and other developing faults that could lead to serious engine damage or a crankcase explosion.

Key Features

  • Continuous monitoring of oil mist density within engine crankcases. 
  • Early warning of abnormal engine conditions and bearing failures. 
  • Optical oil mist detection technology for accurate measurement of oil mist concentration. 
  • Visual and audible alarm functions when preset alarm thresholds are exceeded. 
  • Sampling system using air valves, hoses, and air chambers to monitor multiple crankcase locations. 
  • Widely installed on marine diesel engines and industrial power generation equipment.

Operating Principle

The MK5 continuously samples air from engine crankcases and passes the sample through an optical measuring chamber. Oil mist particles scatter light within the detector, allowing the system to determine the oil mist concentration. When the measured value exceeds the preset alarm threshold, the MK5 activates alarm outputs to alert operating personnel to potentially dangerous conditions.

System Components

Typical MK5 systems consist of:

  • Control Unit
  • Display Unit
  • Sampling Valves
  • Air Chamber
  • Photocell Assembly
  • Lamp Assembly
  • Air Filter and Pressure Regulator
  • Sampling and Exhaust Hoses
  • Alarm and Relay Outputs

These components work together to provide reliable monitoring and protection of diesel engine crankcases.

Support and Spare Parts

As the MK5 is a legacy product, availability of original spare parts is limited. Many operators therefore rely on reconditioned MK5 systems and refurbished replacement components to maintain existing installations. This provides a practical solution where upgrading to a newer MK6 or MK7 system is not immediately required.

System Specifications

Parameter Specification
System Type Oil Mist Detection System (OMD)
Detection Method Optical light-scatter measurement
Application Diesel engine crankcase monitoring
Sampling Method Sequential air sampling from crankcase spaces
Alarm Function Visual and audible alarm on high oil mist density
Protection Purpose Early warning of bearing failure and crankcase explosion risk
Installation Marine and industrial diesel engines
Monitoring Multiple crankcase compartments via sampling system

Detection Performance

Parameter Specification
Oil Mist Particle Size Approximately 0.5 to 5 microns
Minimum Detectable Oil Mist Density Approximately 0.05 mg/litre
Explosive Oil Mist Range Typically 30 to 50 mg/litre depending on oil type
Measurement Principle Light scattering by suspended oil particles

Electrical Components

Component Part Number
Main PCB 53569-110
Display Unit 28781-002
Power Supply Assembly 45626-113
Solid State Relay 27480-K008
Relay MK5 27489-073
Programmable IC4 P52100
Power Supply Select Card 39832-704

Pneumatic Components

Component Part Number
Pressure Regulator & Filter Assembly 24124-201
Air Filter Element 24124-202
Pressure Switch 45625-131
Air Valve Assembly 45625-130
Sample Valve Assembly 45625-155
Pressure Gauge B4112-002

Downloads for Kidde Graviner MK5 Oil Mist Detector System.

Below you will find all downloads available for the Kidde Graviner MK5 Oil Mist Detector System. If you need any help in finding a file that is not in this list, please do not hesitate to contact us.
There are currently no downloads available for Kidde Graviner MK5 Oil Mist Detector System.

Related products

Need some help with your project?

Send an enquiry or contact us directly and we will try our best to help you.