Sensepoint XCD RFD

Honeywell Sensepoint XCD RFD Remote Flammable Detector


The Honeywell Sensepoint XCD RFD (Remote Flammable Detector) has been specifically designed for use with remotely mounted flammable gas sensors. This configuration is ideal for applications where the sensor is required to be mounted remotely from the Transmitter in areas where temperatures are well above ambient (up to 150°C/302°F) or that are difficult to access. The transmitter can be mounted at a suitable location away from this area where it is easy to access, view its display and interact with via the user interface.

The Honeywell Sensepoint XCD RFD is your most flexible, practical choice for remote flammable gas monitoring in Class I Division 1 areas. The Sensepoint XCD RFD adds safety, productivity and cost efficiency to an operation by extending intelligent, simplified gas monitoring to hard-to-reach areas.

Honeywell Sensepoint XCD RFD Remote Flammable Detector

Please contact us for more information.
Poison-resistant catalytic bead sensors offer reliable, long-lasting sensing life in an explosion-proof assembly
Low power consumption, reducing cost of ownership
Accurate detection with fast response
Mount transmitter in easy to access area even if sensor is located in difficult or restricted access area
Mount sensor up to 100 feet from transmitter
Mounting hardware available for pipe, duct and junction box installations
Selectable sink or source 4-20mA output.

Benefits:
Easy to read tri-color backlit display with digits, bar graph and icons
Fully configurable via non-intrusive magnetic switches
Auto-inhibit during maintenance prevents false alarms
Common transmitter platform: monitor full range of flammable gases
Longer sensor life compared to electrochemical sensors
Simple operation cuts training costs
Reduced spares and stock costs
Non-intrusive, one-man operation reduces maintenance cost
Optional Modbus adds diagnostic capabilities
Advanced intelligence to further reduce costs.
Input voltage range: 16 to 32VDC (24VDC nominal)
Max. power consumption: Max. 5 Watts. at 24Vdc
Current output: 4-20mA (Source or Sink)
≥0.0<1.0 mA: Fault
4.0 mA to 20.0 mA: Inhibit
(during configuration/user settings)
22.0 mA: max. over range
Terminals: 15 x screw terminals suitable for wire diameter
0.5mm2 to 2.5mm 2 (20AWG to 13AWG)
Relays: 3 x 5A@250VAC
Selectable normally open or normally closed (switch)
and energized/de-energized (programmable)
Communication: RS485, Modbus RTU
Material: Epoxy painted aluminium alloy or 316 Stainless Steel
Weight, approx.: Aluminium Alloy LM25: 4.4lbs
316 Stainless Steel: 11lbs
Mounting: Pole or wall mounting
Cable entries: 2 x ¾” NPT
Sensor entries: ¾” NPT

Related products:
Honeywell Gas Detector - Sensepoint XCD
Honeywell Transmitter - XNX.