Damcos Local Power Unit EEx


The Damcos Local Power Unit EEx is designed to control single- and double-acting Damcos actuators. The Local Power Unit EEx is approved according to the ATEX directive 94/9/EC and meets the requirements to be used in hazardous areas. The LPU EEx comes with a Temperature Watchdog, which enables the LPU EEx to operate in hot ambient temperatures and still being able to ensure that the surface temperature of the LPU EEx never exceeds the allowed maximum.

Damcos Local Power Unit EEx

Technical Specifications
Working Pressure 135 bar
Relief valve cracking pressure 150 bar
Safety valve pressure 210 ± 40 bar
Max. running time Up to 10 min. dependent on ambient temp
Enclosure rating IP 68, (3 bar in 24 hours)
Test pressure 225 bar
Ambient temperature 5°C to 70°C ( -25°C to 70°C on request)
Tank volume/ utility volume approx. 300 ml. / 120 ml.
Weight 18 kg

Please contact us for more information.